COMfortel 1400 - Firmware Version 1.4 - COMfortel Set V3.6 - Operation and Configuration V01 04/2014 25
Important Information
Possible Number of System Telephones on Auerswald PBXs
Possible Number of System Telephones on
Auerswald PBXs
Important:
The power consumption of the terminals on the internal S
0
and U
P0
ports on
Auerswald PBXs may not exceed the listed values in the following table.
If using the PBXs COMpact 5000/R and COMmander 6000/R/RX, the max.
power distribution also includes the a/b ports. For each connected analogue
subscriber, you must deduct 1 W from the max. power distribution.
Important: Only available for operation on the PBXs COMpact 5000/R and
COMmander 6000/R/RX (with Firmware 6.0A or later): During a call, the
COMfortel 1400 allows you to accept another call and record it simultane-
ously on the local answering machine. When a second call is signalled as
waiting, the PBX reserves the second call channel of the internal S
0
port for
this function. At this particular time, a second telephone at the same port
cannot initiate a call, accept an incoming call and pick up a call. Simultaneous
call acceptance and recording by the local answering machine is not possible
while another telephone is on a call at the same port. In order to ensure that
the full scope of functions is available, you should connect only 1 telephone
per port.
PBX Max. power distribution
of the total of all internal
S
0
and U
P0
ports
Max. no. of telephones
without wall-mounted
power supply
COMpact 3000 analogue/
ISDN/VoIP
2,5 W 1
COMpact 2206 USB 4 W 2
COMpact 4410 USB 12 W (4 W per port) 6 (2 telephones per port)
COMpact 5010 VoIP 8 W (4 W per port) 4 (2 telephones per port)
COMpact 5020 VoIP 24 W (4 W per port) 12 (2 telephones per port)
COMpact 5000/R 24 W (4 W per port) 12 (2 telephones per port)
COMmander 6000/R 60 W (4 W per port) 30 (2 telephones per port)
COMmander 6000 RX 160 W (4 W per port) 80 (2 telephones per port)